XPANEL panels
Circular and hexagonal panels in 18 catalogue sizes and 24 to 120 W. Opal or microprismatic diffuser, suspended or surface mounted, with dual-emission versions.
- 24 – 120 W
- Power range
- 18
- Catalogue sizes
- 12
- Codes with UGR < 19
- 39
- Codes in the series
The models
9 models, all in view. The catalogue lists no recessed version of this series.
In view
In view: on the slab or hung on wire, with the body as part of the space.
39 codes| Model | Dimensions | Optic | Power | Codes |
|---|---|---|---|---|
| XP27 | 300 – 600 mm | Not declared | 24 – 48 W | 3 |
| XP62P | 450 – 1200 mm | Opal | 30 – 80 W | 4 |
| XP65P | 450 – 1200 mm | Opal | 30 – 80 W | 4 |
| XH105P Dual emission | 600 – 1200 mm | Opal | 40 – 120 W | 6 |
| XP105P | 450 – 1200 mm | Opal | 30 – 80 W | 4 |
| XP62PM UGR < 19 | 450 – 1200 mm | Microprismatic | 30 – 80 W | 4 |
| XP65PM UGR < 19 | 450 – 1200 mm | Microprismatic | 30 – 80 W | 4 |
| XH105PM Dual emission | 600 – 1200 mm | Microprismatic | 40 – 120 W | 6 |
| XP105PM UGR < 19 | 450 – 1200 mm | Microprismatic | 30 – 80 W | 4 |
The code groups three lines under the XP prefix —this one, XPanel Flat and XPanel Slim— but each has its own catalogue and page. This one covers the circular and hexagonal panels.
Optics and distribution
What sits in front of the LED. The diffuser is declared in position 10 of the code and drives both output and glare control. The catalogue declares no aperture for these diffusers, so no beam is drawn.
- No aperture in catalogue Microprismatic Workstations · UGR < 19 18 codes PM
- No aperture in catalogue Opal Diffuse light, even surface 18 codes P
Colour of the light
39 of the 39 codes in the series declare a colour temperature in the catalogue.
- 3000 K Warm
- 4000 K Neutral
- 5000 K Cool neutral
- 6000 K Cool
- Tunable White (Color Changing) Tunable on site
Dimming
Most of the series is quoted in ON-OFF, DALI and 0-10 V. It is defined at order time: the driver is fitted at the factory and cannot be swapped on site.
- ON/OFF
- No dimming. The base method on every code.
- DALI
- Addressable per luminaire, scenes and sensors.
- 0-10 V / 1-10 V
- Analogue, with separate control wiring.
- Color Changing
- Colour temperature shift, on 24 codes in the series.
Technical specifications
Values for the complete series, taken from the catalogue. For a specific code, the datasheet gives the exact figure.
Photometry
| Efficacy | 100-130 · 100-110 lm/W (±5%) |
|---|---|
| Colour temperature | |
| |
| Colour rendering | Ra > 82 |
| Glare | UGR < 19 with microprismatic · 12 codes |
Electrical
| Power | 24 – 120 W |
|---|---|
| Input voltage | 220 – 240 V · 50/60 Hz |
| LED chip | Everlight 2835 |
| Driver | ON-OFF / DALI / 0-10V / Color Changing · ON-OFF / 1-10V / DALI / Color Changing |
Construction
| Body | Aluminium |
|---|---|
| Sizes | 18 catalogue sizes |
| Diffusers and optics | Microprismatic · Opal |
| Finishes | |
Colour is indicative on screen. To specify, ask for the physical sample. | |
| Emission | Direct, or dual up/down emission · 6 codes |
Installation and life
| Warranty | 5 years |
|---|---|
| Ingress protection | IP20 |
One code, one exact product
Every attribute that defines a variant, in a fixed order of 15 positions. No ambiguity in quotes, purchase orders or specifications.
- CMX 01
- XP 02
- P 03
- 105 04
- 600 05
- T5 06
- 220240 07
- 8 08
- 30 09
- P 10
- SWR 11
- X 12
- DU 13
- W 14
- 60 15
See the full map of the code
- 01 CMX Brand Cromatix
- 02 XP Series XPanel
- 03 P Model P
- 04 105 Profile 105 mm
- 05 600 Size 600 mm
- 06 T5 Chip Everlight 2835
- 07 220240 Voltage 220-240 V
- 08 8 CRI Ra ≥ 80
- 09 30 CCT 3000 K
- 10 P Diffuser Opal
- 11 SWR Mounting Suspended
- 12 X Control Not at this level
- 13 DU Variant Dual emission
- 14 W Finish White
- 15 60 Power 60 W
X means the position does not apply or there is no data: the code always keeps its 15 positions so it stays machine-parseable. Colour temperature is the first two digits of the Kelvin value, and power carries no leading zeros.
Representative configurations
Real catalogue codes, chosen to cover the range of the series: three lengths of the profile with most codes, plus dual emission, the lens and the emergency kit. Flux is power times efficacy from the catalogue itself; where efficacy is a range it is left blank.
| MODEL_CODE | Model | Dimensions | Power | Flux | Efficacy | CRI |
|---|---|---|---|---|---|---|
| CMX-XP-P-105-600-T5-220240-8-30-P-SWR-X-X-W-40 | XH105P | W600 × H105 mm | 40W | — | 100-130lm/W | > 82 |
| CMX-XP-P-105-900-T5-220240-8-30-P-SWR-X-X-W-60 | XH105P | W900 × H105 mm | 60W | — | 100-130lm/W | > 82 |
| CMX-XP-P-105-1200-T5-220240-8-30-P-SWR-X-X-W-80 | XH105P | W1200 × H105 mm | 80W | — | 100-130lm/W | > 82 |
| CMX-XP-PM-105-450-T5-220240-8-30-PM-SFC-X-X-W-30 | XP105PM | D450 × H105 mm | 30W(Down) | — | 100-110lm/W | > 82 |
| CMX-XP-P-105-600-T5-220240-8-30-P-SWR-X-DU-W-60 | XH105P | W600 × H105 mm | 60W | — | 100-130lm/W | > 82 |
| CMX-XP-X-27-300-T5-220240-8-30-X-SFC-X-X-W-24 | XP27 | Ø300 × H27 mm | 24W | — | 100-130lm/W | > 82 |
Photometry and documentation
Photometry is a measurement, not a description: an IES or LDT file corresponds to one physical configuration and changes with length, optic, diffuser and colour temperature.
That is why we do not publish a single series-wide file. Tell us which configuration you are evaluating and we will send the right one, together with the datasheet for that code.
XPANEL in project
Frequently asked questions
Which shapes are in this series?
Circular and hexagonal, in 18 catalogue sizes. The low-profile rectangular ones are in XPanel Flat and XPanel Slim, each with its own page.
Is it suitable for screen-based offices?
Yes, with the microprismatic diffuser: 12 codes declare UGR < 19. The opal ones give more output but carry no UGR figure.
Is there a version that also lights the ceiling?
Yes. 6 codes in the series are dual emission, with output up and down. It is declared in position 13 of the code.
How do I get the photometry for a Dialux calculation?
Write to us with the complete MODEL_CODE and we will send the matching IES or LDT file.
Tell us about the project
If the requirement is already defined, the length and colour temperature are enough to reach a concrete proposal. If you are still exploring, we start from what the light has to resolve.