5-year warranty on all series Own factory · Zhongshan, China sales@cromatix-lighting.com
← All series XPANEL Series

XPANEL panels

Circular and hexagonal panels in 18 catalogue sizes and 24 to 120 W. Opal or microprismatic diffuser, suspended or surface mounted, with dual-emission versions.

24 – 120 W
Power range
18
Catalogue sizes
12
Codes with UGR < 19
39
Codes in the series

The models

9 models, all in view. The catalogue lists no recessed version of this series.

LS

In view

In view: on the slab or hung on wire, with the body as part of the space.

39 codes
Model Dimensions Optic Power Codes
XP27 300 – 600 mm Not declared 24 – 48 W 3
XP62P 450 – 1200 mm Opal 30 – 80 W 4
XP65P 450 – 1200 mm Opal 30 – 80 W 4
XH105P Dual emission 600 – 1200 mm Opal 40 – 120 W 6
XP105P 450 – 1200 mm Opal 30 – 80 W 4
XP62PM UGR < 19 450 – 1200 mm Microprismatic 30 – 80 W 4
XP65PM UGR < 19 450 – 1200 mm Microprismatic 30 – 80 W 4
XH105PM Dual emission 600 – 1200 mm Microprismatic 40 – 120 W 6
XP105PM UGR < 19 450 – 1200 mm Microprismatic 30 – 80 W 4

The code groups three lines under the XP prefix —this one, XPanel Flat and XPanel Slim— but each has its own catalogue and page. This one covers the circular and hexagonal panels.

Optics and distribution

What sits in front of the LED. The diffuser is declared in position 10 of the code and drives both output and glare control. The catalogue declares no aperture for these diffusers, so no beam is drawn.

  • No aperture in catalogue Microprismatic Workstations · UGR < 19 18 codes PM
  • No aperture in catalogue Opal Diffuse light, even surface 18 codes P

Colour of the light

39 of the 39 codes in the series declare a colour temperature in the catalogue.

  • 3000 K Warm
  • 4000 K Neutral
  • 5000 K Cool neutral
  • 6000 K Cool
  • Tunable White (Color Changing) Tunable on site

Dimming

Most of the series is quoted in ON-OFF, DALI and 0-10 V. It is defined at order time: the driver is fitted at the factory and cannot be swapped on site.

ON/OFF
No dimming. The base method on every code.
DALI
Addressable per luminaire, scenes and sensors.
0-10 V / 1-10 V
Analogue, with separate control wiring.
Color Changing
Colour temperature shift, on 24 codes in the series.

Technical specifications

Values for the complete series, taken from the catalogue. For a specific code, the datasheet gives the exact figure.

Photometry

Efficacy 100-130 · 100-110 lm/W (±5%)
Colour temperature
  • 3000 K
  • 4000 K
  • 5000 K
  • 6000 K
  • Tunable White (Color Changing)
Colour rendering Ra > 82
Glare UGR < 19 with microprismatic · 12 codes

Electrical

Power 24 – 120 W
Input voltage 220 – 240 V · 50/60 Hz
LED chip Everlight 2835
Driver ON-OFF / DALI / 0-10V / Color Changing · ON-OFF / 1-10V / DALI / Color Changing

Construction

Body Aluminium
Sizes 18 catalogue sizes
Diffusers and optics Microprismatic · Opal
Finishes
  • White
  • Black
  • Silver
  • Grey
  • Custom

Colour is indicative on screen. To specify, ask for the physical sample.

Emission Direct, or dual up/down emission · 6 codes

Installation and life

Warranty 5 years
Ingress protection IP20

One code, one exact product

Every attribute that defines a variant, in a fixed order of 15 positions. No ambiguity in quotes, purchase orders or specifications.

  1. CMX 01
  2. XP 02
  3. P 03
  4. 105 04
  5. 600 05
  6. T5 06
  7. 220240 07
  8. 8 08
  9. 30 09
  10. P 10
  11. SWR 11
  12. X 12
  13. DU 13
  14. W 14
  15. 60 15
See the full map of the code
  1. 01 CMX Brand Cromatix
  2. 02 XP Series XPanel
  3. 03 P Model P
  4. 04 105 Profile 105 mm
  5. 05 600 Size 600 mm
  6. 06 T5 Chip Everlight 2835
  7. 07 220240 Voltage 220-240 V
  8. 08 8 CRI Ra ≥ 80
  9. 09 30 CCT 3000 K
  10. 10 P Diffuser Opal
  11. 11 SWR Mounting Suspended
  12. 12 X Control Not at this level
  13. 13 DU Variant Dual emission
  14. 14 W Finish White
  15. 15 60 Power 60 W

X means the position does not apply or there is no data: the code always keeps its 15 positions so it stays machine-parseable. Colour temperature is the first two digits of the Kelvin value, and power carries no leading zeros.

Representative configurations

Real catalogue codes, chosen to cover the range of the series: three lengths of the profile with most codes, plus dual emission, the lens and the emergency kit. Flux is power times efficacy from the catalogue itself; where efficacy is a range it is left blank.

MODEL_CODE Model Dimensions Power Flux Efficacy CRI
CMX-XP-P-105-600-T5-220240-8-30-P-SWR-X-X-W-40 XH105P W600 × H105 mm 40W — 100-130lm/W > 82
CMX-XP-P-105-900-T5-220240-8-30-P-SWR-X-X-W-60 XH105P W900 × H105 mm 60W — 100-130lm/W > 82
CMX-XP-P-105-1200-T5-220240-8-30-P-SWR-X-X-W-80 XH105P W1200 × H105 mm 80W — 100-130lm/W > 82
CMX-XP-PM-105-450-T5-220240-8-30-PM-SFC-X-X-W-30 XP105PM D450 × H105 mm 30W(Down) — 100-110lm/W > 82
CMX-XP-P-105-600-T5-220240-8-30-P-SWR-X-DU-W-60 XH105P W600 × H105 mm 60W — 100-130lm/W > 82
CMX-XP-X-27-300-T5-220240-8-30-X-SFC-X-X-W-24 XP27 Ø300 × H27 mm 24W — 100-130lm/W > 82

Photometry and documentation

Photometry is a measurement, not a description: an IES or LDT file corresponds to one physical configuration and changes with length, optic, diffuser and colour temperature.

That is why we do not publish a single series-wide file. Tell us which configuration you are evaluating and we will send the right one, together with the datasheet for that code.

5 Years warranty across the series
Request photometry Download the brochure

Answered within one business day

XPANEL in project

Forus Offices
Forus Offices Circular panel over the lounge area Architecture: Armas Elton Arquitectos · Lighting design: Diseño de Luz
Rosen Showroom
Rosen Showroom Circular panels at varying heights in the showroom Lighting design: Luxia

Frequently asked questions

Which shapes are in this series?

Circular and hexagonal, in 18 catalogue sizes. The low-profile rectangular ones are in XPanel Flat and XPanel Slim, each with its own page.

Is it suitable for screen-based offices?

Yes, with the microprismatic diffuser: 12 codes declare UGR < 19. The opal ones give more output but carry no UGR figure.

Is there a version that also lights the ceiling?

Yes. 6 codes in the series are dual emission, with output up and down. It is declared in position 13 of the code.

How do I get the photometry for a Dialux calculation?

Write to us with the complete MODEL_CODE and we will send the matching IES or LDT file.

Tell us about the project

If the requirement is already defined, the length and colour temperature are enough to reach a concrete proposal. If you are still exploring, we start from what the light has to resolve.